Test Benches
 AMR
 Data Logger
 MUN-1
 MUN-3
 Valve Keys
 FORX
 Thrust Buster
 Strainers
 Zinc Caps
 Valve Locks
 Test Spools
 Insert Stiffeners
 Drill Taps
 Flanges
 
 
 

 

MUN-3
3" X 5/8" UTILITY SERVICE ANALYZER

Specification Sheet

Description: Consists of a 3" turbine meter and a 5/8" X 3/4" positive displacement meter, resetable LCD totalizer on both meters, 3" ball valve, 3/4" valve and a pressure gauge. The 3" aluminum meter tube is equipped with a stainless steel flow restriction plate and cast aluminum handles. The test unit is equipped with a brass National Standard Fire Hose swivel coupling on the inlet and a National Standard Fire Hose nipple on the outlet.

Installation: Directly adaptable to 2 1/2" X 3" National Standard Fire Hose coupling threads. The meter must be at a full flow of liquid and three feet of straight inlet hose for proper accuracy. Meter must be rigidly secured prior to starting test.

Rotor: Injection molded thermoplastic and is permanently attached to the rotor shaft. The rotor rotates on two stationary bearings and utilizes 15 blades that are molded at a precision helix angle to provide extreme accuracy at low flow rates and accurately register across the operating range of the meter. The rotor, which is the only moving part in the meter, electronically drives the sensor output which is proportional to the flow through the meter.

Bearings: Stationary mounted precision ground carbon bearings located at each end of the rotating tungsten carbide rotor shaft inside the measuring chamber. The bearings are located to provide uniform loading of the rotor, thus extending life and providing extreme accuracy during the life of the meter. Dual ceramic thrust bearings insure long life registration in both forward and reverse flow directions.

**Remote Reading Available Upon Request.

Materials of Construction

Magnets Permanent Ceramic Type
Rotor Bearings Carbon
Rotor Shaft Tungsten Carbide
Rotor Injection Molded Thermoplastic
Measuring Chamber Injection Molded Thermoplastic
Bolts Stainless Steel
Strainer Screen Stainless Steel
Flow Restriction Plate Stainless Steel
Meter Head 319 Cast Aluminum
Meter Tube 319 Cast Aluminum

 

Specifications:

Accuracy Plus or Minus 1.5% of actual flow within the range specified
Pressure Range Up to 150 PSI maximum working pressure
Temperature Range 120° F Maximum
Minimum Flow 1/4 GPM
Maximum Flow 700 GPM. Each meter is rated for 10% to 15% of the total time the meter is operating.
Intermittent Flow 450 GPM
Totalizer Standard: Gallons, Cubic Feet, and Liters


Copyright © 1997 Floyd S. Salser, Jr and Associates: D/B/A Mars Company. All rights reserved.
Revised: August 06, 2004.